STOPPERS
CODE | SUIT WIRE | BEFORE SWAGE DIA | AFTER SWAGE DIA | STARTS SLIPPING (KG) |
CP-115S | 1.5MM | 5.1 | 3.5 | 195 |
CP-130S | 3.2MM | 6.35 | 5 | 340 |
CP-140S | 4.0MM | 10.5 | 6.8 | 545 |
CP-150S | 5.0MM | 10.9 | 7,5 | 725 |
Use normal hand swage tool for crimping stoppers, remember to use the hole one size below the wire size, for example when crimpping 3mm wire rope use the 2mm hole on the tool.
Please note that although hand crimping can give excellent results it is not suitable for wire used for lifting purposes.
Use approved methods only.
Find Hand Swages In Aluminium on page 67 of the Bridco Catalogue (PDF).
CODE | SUIT WIRE | BEFORE SWAGE DIA | AFTER SWAGE DIA | STARTS SLIPPING (KG) |
CP-115S | 1.5MM | 5.1 | 3.5 | 195 |
CP-130S | 3.2MM | 6.35 | 5 | 340 |
CP-140S | 4.0MM | 10.5 | 6.8 | 545 |
CP-150S | 5.0MM | 10.9 | 7,5 | 725 |
Number of Sizes | 4 |
---|---|
Page number in Catalogue | 68 |